Elgressy EST chemical-free cooling tower water treatment

Non-chemical water treatment is no longer an experiment. In Thailand, factories, hospitals, data centers and power plants already run their cooling towers without scale inhibitors, biocides or acid dosing, using Elgressy EST (Electrolysis Scale Treatment). This guide explains how EST works, what it saves, what it costs to run, and how to know whether your cooling tower is a good fit.

What is non-chemical water treatment?

Conventional cooling-tower treatment adds chemicals to the water: scale inhibitors, corrosion inhibitors, biocides and often sulfuric acid to control pH. Non-chemical water treatment controls the same problems with a physical process instead. With Elgressy EST the process is electrolysis: a small side-stream of the circulating water flows through an EST reactor, where an electric current makes the hardness (calcium carbonate) precipitate on the reactor wall instead of on your condenser tubes, fill and pipes. The collected scale is scraped off and flushed out automatically.

For a deeper comparison, see Non-Chemical vs Chemical Water Treatment.

The 3 cooling-tower problems: scale, algae and corrosion

Every open cooling tower in Thailand’s hot climate fights the same three problems. Chemical programmes treat each one with a different product; EST controls all three with one system.

Calcium carbonate scale from a cooling water system
Scale
Insulates condenser tubes and raises chiller energy use
Algae and biofouling on a condenser tube sheet
Algae and biofouling
Blocks tubes and fill, and feeds Legionella
Corroded inside of a cooling water pipe
Corrosion
Eats pipes, pumps and tower basins

How Elgressy EST works in 4 steps

How Elgressy EST works: side stream, electrolysis, scale in reactor, auto removal, clean system
How Elgressy EST works – hardness leaves the system as solid scale, without any chemicals
  1. Side-stream: a small part of the circulation flow passes through the EST reactor.
  2. Electrolysis: near the reactor wall the pH rises sharply, so calcium carbonate and other scale-forming minerals precipitate there.
  3. Disinfection: the electrolysis also produces oxidants that control algae, bacteria and biofilm, without adding biocide.
  4. Automatic cleaning: a scraper removes the collected scale and a short flush sends it to drain. Operation is fully automatic and PLC-controlled.
Elgressy EST non-chemical water treatment unit
Elgressy EST unit
Scale collected inside the EST reactor instead of on the condenser
Scale captured inside the EST reactor – not on your condenser

What does non-chemical treatment with EST save?

  • Chemicals: up to 100% of cooling-water chemicals and acid dosing are eliminated. Chemical savings
  • Water: typically 30–60% less make-up water and blow-down, because the tower can run at higher cycles of concentration. Water savings
  • Energy: clean condenser tubes keep the chiller approach temperature low, so chillers use less electricity – an average energy saving of 6.75% and more. Energy savings
  • Maintenance and downtime: no more acid cleaning of condensers and fewer shutdowns. Downtime savings
  • CO2: lower chiller energy use and no chemical production or transport mean a smaller carbon footprint.
  • Equipment life: less scale and corrosion extend the life of chillers, cooling towers, pumps and pipes. Equipment life

Real example: at a Thai food factory, EST removes around 2.2 tonnes of scale a year from the cooling water before it can reach the heat exchangers. Read the AB Food case study.

Small footprint, low maintenance: a one-time investment with quick ROI

  • Small footprint: EST is a compact side-stream unit installed next to the cooling tower. No chemical storage room, dosing pumps or acid tanks are needed.
  • Low maintenance: the reactor cleans itself automatically. Only a periodic manual cleaning is needed, done by ALA or by your own trained staff. No chemical deliveries, no dosing adjustments.
  • Low replacement cost: the main wear parts are the anodes (2-year warranty). The carbon steel reactor tank has a 10-year corrosion warranty, and the system lasts a minimum of 15 years with proper maintenance.
  • One-time investment: instead of paying for chemicals and dosing service every month, you invest once. Savings on chemicals, water, energy, maintenance and downtime give a quick return on investment (ROI) and an attractive internal rate of return (IRR). Thanks to the outstanding durability of EST, the total savings over the system’s life are more than 5 times the investment.

Want to know your payback time? We calculate the ROI and IRR for your own site: free ROI assessment.

Modular: from 200 TR to 50,000 TR power plants

EST is modular. Units are combined in parallel to match the cooling load, so the same proven technology serves:

  • Small HVAC systems from about 200 TR – office buildings, hotels, hospitals and shopping malls,
  • Industrial cooling towers – food and beverage, automotive, packaging and chemical plants,
  • Data centers with 24/7 cooling and strict uptime requirements, and
  • Power plants up to 50,000 TR and more, cooling turbine condensers.

Extra modules can be added later when the plant grows, and the side-stream installation means EST can be installed without stopping the cooling system.

CO2-friendly cooling water treatment

EST also lowers the carbon footprint of your cooling system:

  • Lower chiller energy use: scale-free condenser tubes keep the approach temperature low, so chillers need less electricity (on average 6.75% and more) – and every kWh saved is CO2 saved.
  • No chemicals to produce and transport: no manufacturing, packaging and truck deliveries of inhibitors, biocides and acid.
  • Less water to pump and treat: lower make-up and blow-down volumes reduce the energy used for water supply and wastewater treatment.
  • Clean discharge: chemical-free blow-down water can often be reused, for example for irrigation.

This supports your ESG and carbon-reduction targets, as well as LEED and WELL certification.

Supports LEED and WELL certification

Green building certifications reward exactly what EST delivers. For LEED, higher cycles of concentration and less blow-down support the water-efficiency credits for cooling towers. For WELL, chemical-free disinfection and a clean system support Legionella control in cooling towers. Read more: Cooling tower water treatment for WELL and LEED buildings, LEED certification explained and WELL certification and cooling towers.

How cooling-water treatment with EST supports LEED points
How chemical-free cooling-water treatment supports LEED water-efficiency points

The Elgressy EST-N system has also been checked, examined and approved by the IFC (International Finance Corporation, World Bank Group).

IFC approved Elgressy EST-N systems
Elgressy EST-N – checked, examined and approved by the IFC

Understanding LSI, cycles and corrosion with EST

Water engineers often ask: “If there are no chemicals, will the Langelier Saturation Index (LSI) not go up?” Yes, with EST the cooling water usually stays scale-forming (positive LSI). That is intended: the scale is formed and captured inside the EST reactor, not on the condenser and fill. The real performance indicators are:

  • the amount of hardness removed by the reactor (kg CaCO3 per year),
  • a stable or improving chiller approach temperature, and
  • corrosion rates measured with coupons.
Corroded cooling water pipes
Corrosion without proper control
Cooling water pipes without corrosion after 7 years of Elgressy EST
No corrosion after 7 years with Elgressy EST

The right cycles of concentration (COC) depend on your make-up water: hardness, alkalinity, silica and the materials in your system. Softened, high-alkalinity water behaves differently from hard well water, so we always calculate a water mass balance for each site before recommending a target COC.

Topic Chemical treatment Elgressy EST (non-chemical)
Scale control Inhibitors, acid dosing Scale captured in the EST reactor
Biological control Biocides, chlorine Oxidants from electrolysis
Chemical handling and storage Yes, continuous None
Blow-down water Contains chemicals Chemical-free, often reusable for irrigation
Running cost Chemicals + dosing service Low electricity use + periodic cleaning
Investment Ongoing monthly chemical and service cost One-time investment, quick ROI, lifetime savings > 5× investment
Chiller energy Rises as scale builds up Average saving 6.75% and more
Footprint Chemical storage and dosing station Compact side-stream unit
CO2 footprint Chemical production, transport, higher chiller energy CO2-friendly: lower energy, no chemicals
System life – Minimum 15 years with proper maintenance

Is my cooling tower suitable for EST?

EST suits most open cooling towers, from about 200 TR HVAC systems to 50,000 TR power plants. You are a good candidate if you have:

  • scale on condenser tubes or a rising chiller approach temperature,
  • algae, foam or corrosion problems,
  • high chemical or water costs, or a corporate target to reduce chemicals and water (ESG, LEED, WELL),
  • plans for green financing: Thai banks’ green loan programmes, for example Kasikornbank’s, include energy efficiency and water efficiency as eligible categories.

See also 5 signs your cooling tower needs non-chemical water treatment and our page on cooling tower water treatment in Thailand.

Frequently asked questions

Is non-chemical water treatment really chemical-free?

Yes. EST uses only electricity. No scale inhibitors, corrosion inhibitors, biocides or acid are added to the cooling water.

How much water can I save?

Typically 30–60% of make-up water and blow-down, depending on your make-up water quality and how high the cycles of concentration can safely go.

What maintenance does EST need?

The reactor cleans itself automatically. A periodic manual cleaning is done by ALA or by your trained staff. Year-1 cleaning can be included in the price.

How quickly does EST pay back?

EST is a one-time investment with low running and replacement costs, so savings on chemicals, water, energy and maintenance usually give a quick ROI, and thanks to EST’s durability the lifetime savings are more than 5 times the investment. The exact payback and IRR depend on your site; we calculate them free of charge.

What size of cooling tower can EST treat?

EST is modular: from about 200 TR building HVAC systems up to power plants of 50,000 TR and more, by combining units in parallel.

Does EST help with LEED and WELL?

Yes. Less blow-down supports LEED water-efficiency credits, and chemical-free biological control supports WELL Legionella requirements for cooling towers.

Who supplies and services EST in Thailand?

Aerial Lift Asia Co., Ltd. (watertreatmentasia.com) has been the exclusive distributor of Elgressy Engineering Services Ltd. (Israel, founded 1987) for Southeast Asia since 2010, with commissioning, training and service from Bangkok.

Get a free assessment for your site

Send us your cooling tower data (capacity, circulation flow, Delta T, make-up water analysis) and we will prepare a mass balance and savings estimate for your site, free of charge. Request your free ROI assessment or call 064 284 6598 (English) / 063 957 8383 (Thai).

Leave A Comment

Watertreatmentasia is a subsidiary of Aerial Lift Asia Co.,Ltd.

Aerial Lift Asia is official and exclusive distributor of ELGRESSY for S.E. Asia.

Opening Hours:

Mon – Friday: 8AM – 5PM.
Saturday: 8AM – 12PM.
Sunday: Closed

© 2026 Water Treatment Asia, a subsidiary of Aerial Lift Asia Co., Ltd.
All Rights Reserved
| Disclaimer

[wps_visitor_counter]
Hi! Can I show you around?
Free ROI assessmentประเมิน ROI ฟรี